Near Passive-Zero Energy Ready Ductless Home in Hamilton Ohio

The Need

“John, and Donna are  building a Deltec home built in Hamilton OH. They plan on mini-splits and will have a separately ducted ERV. ” They are most likely planning on seeking Zero Energy Ready Certification.”

Full HVAC Design – Consultant will design the appropriate HVAC systems. Deliverables will include:

  • Manual J Load Calculation: Complete an energy model to determine the amount of heating and cooling requirements the building has. We will generate reports that will show the heating and cooling loads for all zones within the building.
  • Manual S Equipment Selection: Based on the calculations generated from the energy model, we will select properly sized equipment, and will produce a written specification for all heating, ventilation, and air conditioning equipment. This will also include performance and installation specifications for the duct system.
  • Manual D, Duct Design: For any ducted systems in the building, we will design and lay out a properly sized duct system, including registers, to fit within the structure of the building, which will be represented by a single-line diagrammatic scalable floor plan. For ductless systems, we will address distribution issues to ensure that each zone gets the proper amount of heating and cooling.
  • Mechanical ventilation requirements and specification (For low load designs Ventilation system may serve as distribution system)
  • All needed LEED and/or Energy Star HVAC Design Documentation Typical Single Family Design Package

Thermal Performance Design:

  • Wall insulation: R-28: exterior 1″ XPS Rigid foam board, interior between studs: 1.5″ closed cell spray foam, 4″ blown in cellulose
  • Ceiling: no attic: R-45: interior between and over truss rafters: 7″ closed cell spray foam
  • Rim board, sill plate, top foundation area: R-29: interior 4.5″ closed cell spray foam
  • Exterior Walls: R-29 4.5″ closed cell spray foam
  • Basement poured foundation walls & under basement floor slab: exterior R-17 @ 40F 2 layers of 2″ rigid EPS Foam board offset to cover joints
  • Exterior Door: Energy Star Therma Tru door: </= 0.27 U-factor
  • Exterior Windows: Marvin Integrity (Elevate) -Casement -0.27 0.20 Picture- 0.26 0.23
  • Infiltration: 0.5 ACH50
The House

Entire House:

  • Heating: 19568 BTUH
  • Cooling: 9707 BTUH

1St Floor Zone:

  • Heating: 12573 BTUH
  • Cooling: 7184 BTUH

Basement Zone:

  • Heating: 7058 BTUH
  • Cooling: 1851 BTUH

What We Designed/ Specified
Configure

four images of a home renovation stitched together

What the Client Had to Say

We found HVAC 2 Home Performance® through their (Partner) Company Green Building Consulting and immediately had confidence that Jeremy would do a very capable HVAC design for our high performing home. Jeremy provided a complete HVAC solution addressing heating, cooling, humidity control, area heating and whole house ventilation with ERV. I'm confident that this holistic design will provide excellent comfort and great air quality throughout the main floor and full basement of this 2400 sq ft 3 bdrm, 3 bath house. Jeremy was very professional, answered many detailed technical questions, and provided helpful HVAC contractor selection recommendations. It's hard to imagine that an 18,000 btu (1.5 ton) mini-split system can handle the heating & cooling needs of this house but it has proven to do so. We're nearing the end of construction and all elements of the HVAC system have been operating reliably for a couple of weeks now. The construction crew has commented that the house feels very comfortable, and that the basement just doesn't feel like a basement. They've said that temperature is very even throughout the house, and we've taken initial temperature data that proves this with less than a 2o F variation. We're looking forward to collecting more data when the house is complete.

What Project Collaborators Had To Say

Already Have a Plan? Submit Here To Get Started

Upload a set of plans today and let us give you a quote. Within 48 hours you will be provided a full custom quote for the design, and/or test and balance/ commissioning needs for your project. Please specify when uploading what services you would like a proposal for.

Contact Us Today!

Cincinnati: 513-655-2697 Knoxville: 865-855-0903
Upload a File

File(s) size limit is 20MB.

?
Enter the Captcha

By clicking here you consent to receive marketing, customer care, account notification sms from HVAC 2 Home Performance®. Message frequency may vary. Standard Message and Data Rates may apply. Reply STOP to opt out. Reply Help for help. Please click the hyperlinks to read our  Privacy Policy and  Terms and Conditions.

We will not share your opt-in to an SMS campaign with any third party for purposes unrelated to providing you with the services of that campaign. We may share your Personal Data, including your SMS opt-in or consent status, with third parties that help us provide our messaging services, including but not limited to platform providers, phone companies, and any other vendors who assist us in the delivery of text messages. All the above categories exclude text messaging originator opt-in data and consent; this information will not be shared with any third parties.