Zero Energy Ready Ductless HVAC Design in Akron Ohio

The Need

“We have an HVAC design done by an installer, but we are not really satisfied with the system they have suggested- it seems to us like more than is needed for the size and energy efficiency of the house we’ve designed. Would your team be able to provide us with an HVAC spec for the mini-split heat pumps?

Our hope is to heat and cool the house with mini-splits: probably either Daikin or Mitsubishi. We think one unit in the basement, located on the angled wall of the bathroom, one on the first floor, and one unit with two heads on the second floor.”

Full HVAC Design – Deliverables will include:

  • Manual J, Load Calculation: We will complete an energy model to determine the amount of heating and cooling requirements the building has. We will generate reports that will show the heating and cooling loads for all zones within the building.
  • Manual S, Equipment Selection: Based on the calculations generated from the energy model, we will select properly sized equipment, and will produce a written specification for all heating, ventilation and air conditioning equipment. This will also include performance and installation specifications for the duct system.
  • Manual D, Duct Design: For any ducted systems in the building, we will design and lay out a properly sized duct system, including registers, to fit within the structure of the building, which will be represented by a single-line diagrammatic scalable floor plan. For ductless systems, we will address distribution issues to ensure that each zone gets the proper amount of heating and cooling.
  • Mechanical ventilation requirements and specification (for low load designs Ventilation system may serve as distribution system)
  • 2220 Sqft 2 Story with finished basement Single Family Home
  • R-19 Exterior Above Grade Walls
  • R-12.5 Below Grade Superior Wall System with additional R-7.5 Interior Insulating System
  • R-49 Roof Attic Insulation
  • Planned 1.5 ACH 50

Entire House:

  • Heating – 21009 Btuh
  • Cooling- 11611 Btuh

Basement Zone:

  • Heating- 4917 Btuh
  • Cooling – Sensible-2862 Btuh
  • Latent- 404 Btuh
  • Total – 3266 Btuh

1st Flr Zone:

  • Heating-8094 Btuh
  • Cooling- Sensible- 4472 Btuh
  • Latent -160 Btuh
  • Total- 4633 Btuh

2nd flr Zone:

  • Heating – 7997 Btuh
  • Cooling – Sensible-4166 Btuh
  • Latent- 333 Btuh
  • Total- 4500 Btuh

Required Ventilation – 63 CFM

What We Designed/ Specified
Configure

What the Client Had to Say

Jeremy at HVAC 2 Home Performance® was an incredibly valuable asset to our new home construction planning process. As a custom home builder focusing on high performance homes it is difficult to rely just on our heating and cooling contractors to accurately design an efficient system and to price it fairly. Jeremy was able to eliminate that work from us and take it on. He thoughtfully went through our plans with our Architect and took plenty of time to understand how we as the builder were going to detail the air and insulation systems. Jeremy and his team at HVAC 2 Home Performance® then went on to create a detailed multi page explanation of our exact heating and cooling loads, air flow and circulation requirements, fresh air recovery system, and whole house dehumidification system. After that he went one step further and specified the exact mechanical components, line set locations, and duct work locations for each area of the house! Thank you so much for your hard work! - Adam Kilgore, Alair Homes

What Project Collaborators Had To Say

Already Have a Plan? Submit Here To Get Started

Upload a set of plans today and let us give you a quote. Within 48 hours you will be provided a full custom quote for the design, and/or test and balance/ commissioning needs for your project. Please specify when uploading what services you would like a proposal for.

Contact Us Today!

Cincinnati: 513-655-2697 Knoxville: 865-855-0903
Upload a File

File(s) size limit is 20MB.

?
Enter the Captcha

By clicking here you consent to receive marketing, customer care, account notification sms from HVAC 2 Home Performance®. Message frequency may vary. Standard Message and Data Rates may apply. Reply STOP to opt out. Reply Help for help. Please click the hyperlinks to read our  Privacy Policy and  Terms and Conditions.

We will not share your opt-in to an SMS campaign with any third party for purposes unrelated to providing you with the services of that campaign. We may share your Personal Data, including your SMS opt-in or consent status, with third parties that help us provide our messaging services, including but not limited to platform providers, phone companies, and any other vendors who assist us in the delivery of text messages. All the above categories exclude text messaging originator opt-in data and consent; this information will not be shared with any third parties.